The Stacke room-in-room strongroom system in modular design and construction

Resistance grade CEN VIII - XI (CD)

VdS tested + certified in accordance with the European standard EN 1143-1.
ECBS Euro certified in accordance with EN 1143-1.

Stacke is a leading manufacturer performing the planning, production and installation of industrially pre-fabricated strongrooms.

Their modular design offers many advantages over the classical strongroom in cast in-situ construction:

  • The modular design and construction reduces, e.g., the thickness of a solid 500 mm wall to 150 mm and nevertheless provides the same resistance to burglary.
  • The modular design and construction – being compact and, therefore, comparatively light – is a room-in-room system which can be installed in existing rooms by means of dry construction techniques without high technical expenditure even at a later date and can, if necessary, anytime be removed again.
  • The compact walls offer the benefit of larger useful space – an advantage for planning – so that such an investment will pay off.
  • Strongrooms in modular design are of stable value, in the event of a change of location, they can be disassembled without any problems and reused and reassembled at another place.
  • Under specific conditions, a mixed design and construction may be favourable. In this case, e.g. walls consisting of pre-fabricated elements are combined with a floor cast in-situ – or vice versa.
  • These strongrooms can be used at any place where valuables need to be protected and locked away. Nowadays, their scope of applications goes far beyond their use in financial institutions and also comprises applications by companies transporting cash and valuables, industrial and business companies, pharmaceutical companies and private persons.
  • Stacke is offering a full range of VdS tested resistance grades and thus enables solutions to be tailored to different individual security requirements.

In every specific project, the local situation and the allowed dimensions are considered in a custom-made individual solution.

 

Following: Examples of the arrangement of a system (ground plan, skeleton view).

EL ST 100 VIII

  • EL-ST-100-WG
    VdS tested + certified in accordance with the European standard EN 1143-1; ECBS Euro certified in accordance with EN 1143-1.
  • Resistance grade: CEN VIII, 825 RU, 100 mm wall thickness
  • Weight: approx. 326 kg/m²
  • Dimensions/elements: 550 mm standard width, special widths and lengths as required
  • Paint coating: primed only
  •  

EL ST 125 (KB) IX

  • EL-ST-125-WG
    VdS tested + certified in accordance with the European standard EN 1143-1; ECBS Euro certified in accordance with EN 1143-1.
  • Resistance grade: CEN IX, 1,050 RU, 125 mm wall thickness
  • Optional: CD protection against 10,000 RU crown bits
  • Weight: approx. 376 (390) kg/m²
  • Dimensions/elements: 550 mm standard width, special widths and lengths as required
  • Paint coating: primed only

 

EL ST 150 (KB) X

  • EL-ST-150-WG
    VdS tested + certified in accordance with the European standard EN 1143-1; ECBS Euro certified in accordance with EN 1143-1.
  • Resistance grade: CEN X, 1,350 RU, 150 mm wall thickness
  • Optional: CD protection against 10,000 RU crown bits
  • Weight: approx. 457 (471) kg/m²
  • Dimensions/elements: 550 mm standard width, special widths and lengths as required
  • Paint coating: primed only

 

EL ST 230 (KB) XI

  • EL-ST-230-WG
    VdS tested + certified in accordance with the European standard EN 1143-1; ECBS Euro certified in accordance with EN 1143-1.
  • Resistance grade: CEN XI, 2,000 RU, 230 mm wall thickness
  • Optional: CD protection against 10,000 RU crown bits
  • Weight: approx. 680 (694) kg/m²
  • Dimensions/elements: 550 mm standard width, special widths and lengths as required
  • Paint coating: primed only

Rechte Maustaste, Ziel speichern unter... 

tresor-raum-in-raum
Euroline strongrooms

The Stacke room-in-room strongroom system in modular design and construction

Resistance grade CEN I-VI

VdS tested + certified in accordance with the European standard EN 1143-1.

Stacke is also a leading manufacturer per-forming the planning, production and installation of industrially pre-fabricated strongrooms in modular design and construction.

The new Stacke modular series in the resistance grades I to VI supplements the previously existing range from VIII to XI and thus enables the user to get new problem solutions for an individually matched pro-tection of valuables in rooms with tested and defined security.

  • With wall thicknesses ranging from just 50-70 mm, the modular design and construction – being compact and, therefore, comparatively light – is a room-in-room system which can be installed in existing rooms by means of dry construction techniques without high technical expenditure even at a later date and can, if necessary, any time be removed again.
  • The compact walls offer the benefit of larger useful space – an advantage for planning – so that such an investment will pay off.
  • Strongrooms in modular design are of stable value; in the event of a change of location, they can be dis-assembled without any problems and reassembled and reused at another place.
  • These strongrooms can be used at any place where valuables need to be protected and locked away. The range of application covers industrial and business companies, pharmaceutical companies, companies transporting cash and valuables, public authorities and private persons.

In every specific case, the local situation and the allowed dimensions are considered in a custom-made individual solution.

EL ST 50 I + 60 I

rauminraum-wg102

  • VdS-tested + certified in accordance with the European standart EN 1143-1
  • Resistance grade: CEN I, 50 RU, wall thickness 50 mm resp. 60 mm
  • Weight: approx. 162 kg/m² resp. approx 187 kg/m²
  • Dimensions/elements: 550 mm standard width, special widths and lengths as required
  • Spread: max. 2,70 m resp. max. 3,00 m
  • Paint coating: primed only

EL ST 60 II

rauminraum-wg202

  • VdS-tested + certified in accordance with the European standart EN 1143-1
  • Resistance grade: CEN II, 80 RU, wall thickness 60 mm
  • Weight: approx.190 kg/m²
  • Dimensions/elements: 550 mm standard width, special widths and lengths as required
  • Spread: max. 3,00 m
  • Paint coating: primed only

EL ST 70 III

rauminraum-wg302

  • VdS-tested + certified in accordance with the European standart EN 1143-1
  • Resistance grade: CEN III, 120 RU, wall thickness 70 mm
  • Weight: approx. 215 kg/m²
  • Dimensions/elements: 550 mm standard width, special widths and lengths as required
  • Spread: max. 3,50 m
  • Paint coating: primed only

EL ST 70 V + 70 VI

rauminraum-wg5-602

  • VdS-tested + certified in accordance with the European standart EN 1143-1
  • Resistance grade: CEN V + VI, 270 + 400 RU, wall thickness 70 mm
  • Weight: approx. 229 kg/m²
  • Dimensions/elements: 550 mm standard width, special widths and lengths as required
  • Spread: max. 4,00 m
  • Paint coating: primed only

 

Rechte Maustaste, Ziel speichern unter... 

Resistance grade CEN VIII

Euroline strongrooms in modular design

The object of the year 2004: A strongroom of huge dimensions made of CEN VIII modules in mixed design and construction for a British pharmaceutical group

gb1-skelett
The steel skeleton during construction

A strongroom for a British pharmaceutical group, made of CEN VIII modules in mixed design and construction featuring huge dimensions:

  • a height of 9.50 m, a width of 13.40 m, a length of 23.00 m,
    a weight of approx. 350 tons
  • and with 940 m² of modular walls
  • a 4.40 m high and 2.50 wide strongroom door weighing 8.5 tons
  • an electrically movable lattice day door
  • an emergency door with electronic emergency unlocking
  • and the steel construction to be supplied.

Development, planning and logistics placed extremely high demands on the engineering, all specialists and members of staff involved.

Its construction in accordance with the requirements and in due time are proof of the excellent performance of the company and its know-how as a general contractor for the total object.

gb2-wand
Installation of the CEN VIII wall modules

gb3
The front and side of the fully assembled strongroom, with the strongroom door at the front

gb4
A close-up of the side and back wall with the emergency door

gb5-tuer
The 4.40 m high strongroom door, during final assembly at the manufacturer`s works before shipment